Sun Fire X4150 Tools And Drivers

Posted on
Sun Fire X4150 Tools And Drivers Rating: 3,0/5 4727reviews

Recovery from a Failed ILOM Upgrade for Sun Fire X4. X4. 45. 0 Servers. Recovery from a Failed ILOM Upgrade for Sun Fire X4. X4. 45. 0 Servers. Use the procedures in this section to recover from a failed upgrade. E19150-01/820-2709-13/figures/Chap1-5.jpg' alt='Sun Fire X4150 Tools And Drivers' title='Sun Fire X4150 Tools And Drivers' />Sun Fire X4150 Tools And DriversA failed upgrade has occurred if any of the following messages appears during the upgrade process. Firmware size incorrect. Incorrect image type. BIOS upgrade failed. Before You Begin. Your server should be set up to view and respond to system boot and POST messages and prompts. Sega Mega Drive Collection Ps2 Iso there. Recovering From a Corrupt SPIf the SP does not boot or is inaccessible, you must recover the SP firmware to ELOM and repeat the migration process. This section lists two SP firmware recovery methods for the Sun Fire X4. X4. 45. 0 servers. Note Use this procedure for the Sun Fire X4. X4. 45. 0 servers only. Set up the server to view and respond to boot and POST messages. Power on the server, and insert the Tools and Drivers v. CD into the servers CDDVD drive. The server boots from the Tools and Drivers CD. Iv Sun Fire X4140, X4240 and X4440 Servers Windows Operating System Installation Guide June 2009 Copy Driver Files to NonFloppy Media 18 Copy Drivers to Non. Download the latest drivers for your Sun Microsystems SUN FIRE X4170 SERVER to keep your Computer uptodate. The Sun Fire X4150. Sun Fire and Sun Blade. Sun. Watch the POST messages, and when prompted, press F2 to enter the BIOS Setup Utility. The BIOS Setup Utility main screen appears. Ensure that the CDDVD is the primary boot device. E19121-01/sf.x4140/820-2401-14/figures/servicing-dorado1u-motherboard-18.jpg' alt='Sun Fire X4150 Tools And Drivers' title='Sun Fire X4150 Tools And Drivers' />Copy the transitional ELOM remote flash file from the Tools and Drivers CD to your TFTP server. Server. Sun Fire X4150 remoteflashilom2. Oracle Sunfire x4150 Drivers. I have looked on the oracle website and i cant find the 2012 server drivers for the x4150. Tools drivers DVD. Sun Fire X4140 Server Chassis Overview. For more detailed information about ports and their uses, see the Sun Fire X4150 Server Installation Guide. Use the arrow keys to navigate the screens. Save and exit the BIOS Setup Utility and boot the server. The server boots from the CD, and the Tools and Drivers main menu appears. Select the option to exit to DOS. The DOS prompt appears. Navigate to the recoveryelom directory. Run the recovery. A menu appears with the following options. To recover both SP and BIOS firmware. To recover SP3. To recover BIOS9. Select the option to recover the SP and BIOS firmware option 1. The recovery process starts. When the SP recovery finishes, power on and boot the server. The SP is recovered to the lastest working version of ELOM. Download the latest drivers for your Sun Microsystems SUN FIRE X4150 to keep your Computer uptodate. Sun Fire X4150, X4250, and X4450 Servers Diagnostics Guide. Sun Fire xxx Server Tools and Drivers CD. X4250, and X4450 Servers Diagnostics Guide. Repeat the migration by updating to the transitional ELOM see Chapter 2. Note Use this procedure for the Sun Fire X4. X4. 45. 0 servers only. Prepare the DOS bootable media. Set up the server to view and respond to boot and POST messages. Copy the contents of the recoveryelom directory from the Tools and Drivers CD to the DOS bootable media. Boot the server with the DOS bootable media. The server boots, and a DOS prompt appears. E19121-01/sf.x4150/820-1852-13/figures/servicing-doradi-motherboard-12.jpg' alt='Sun Fire X4150 Tools And Drivers' title='Sun Fire X4150 Tools And Drivers' />To flash the SP firmware, run the recovery. DOS prompt. recovery. When the SP recovery finishes, power on and boot the server. The SP is recovered to the lastest working version of ELOM. Repeat the migration by updating to the transitional ELOM see Chapter 2. Recovering From a Corrupt BIOS If the server does not boot or if the BIOS is inaccessible, you must recover the BIOS firmware. This section describes two BIOS firmware recovery methods for the Sun Fire X4. X4. 45. 0 servers. Use one of the following recovery methods. The following procedures use the flash file package to recover the BIOS firmware. The flash file package is a combined firmware image file that flashes both the SP and the BIOS. Verify whether the SP has the ELOM or ILOM firmware installed, and recover the matching ELOM or ILOM BIOS firmware. Torrent Imagine You And Me Song. Note Use this procedure for the Sun Fire X4. X4. 45. 0 servers only. Use the web GUI or the CLI to determine the type of SP firmware ELOM or ILOM installed. Enter the SP address in a web browser. The login screen appears. Note the title of the login screen. If the title states, Embedded Lights Out Manager, the SP is ELOM based. If the title states, Integrated Lights Out Manager, the SP is ILOM based. Log in to the web GUI. The main screen appears. To view version information, click the System Information tab. The transitional ELOM will appear as version 4. Log into the SP via ssh. The SP version is displayed, and the CLI prompt appears. To view more detailed version information enter the version command at the CLI prompt. The transitional ELOM will appear as version 4. Use the following table to determine which flash file package to use. If the SP is ELOM use the transitional ELOM BIOS, and if the SP is ILOM use the ILOM combined firmware image. Transitional ELOM file. ILOM Combined firmware image file. X4. 15. 0 0. 264. Sun Fire X4. 45. 0. X4. 45. 0 4. 503. B1. 7X4. 45. 0 2. You have the following recovery options for method 1. To Recover the ELOM BIOS Firmware Using the Web GUI. Ensure that the serv is in standby power mode. Copy the transitional ELOM remote flash file from the Tools and Drivers CD to a device that is accessible to your server see Chapter 1. The transitional ELOM remote flash file is located on the Tools and Drivers CD at. X4. 15. 0 0. 264. Sun Fire X4. 45. 0. X4. 45. 0 4. 503. B1. 73. In your browsers address bar, type the IP address of the servers SP. IP address of the SP. The ELOM web GUI login screen appears. Log in as root or as an account with administrator privileges. The ELOM web GUI main menu screen appears. If the server is powered on, use the following steps to place the server in standby power mode. The server must be powered off and in standby power mode. From the main menu, click the Remote Control tab. The Remote Control submenu tabs appear. Click the Remote Power Control tab. The Remote Power Control submenu screen appears. Select the Power Off radio button, and click the Submit button. This action powers off the server. From the main menu, click the Maintenance tab. The Maintenance submenu tabs appear. Click the Firmware Upgrade tab. The Firmware Upgrade screen appears. Click the Enter Firmware Upgrade Mode button. Locate the firmware upgrade file. Click Browse and locate the transitional ELOM file that you copied in Step 2. Select the file and then click Open. Accept the default, Clear BIOS CMOS. To start the firmware upgrade, click the Update firmware button. The firmware upgrade process updates the BIOS and SP firmware. After the upgrade is finished, the ELOM boots and the web session starts. The BIOS version information is updated when the host is powered on. When the process finishes, power on and boot the server. The BIOS version information is updated once the server is powered on. Repeat the ELOM to ILOM migration process. To Recover the ELOM BIOS Firmware Using the CLI. Ensure that the server is in standby power mode. Copy the transitional ELOM remote flash file from the Tools and Drivers CD to your TFTP server. X4. 15. 0 0. 264. Sun Fire X4. 45. 0. X4. 45. 0 4. 503. B1. 73. Access the CLI. For CLI access options, see the Embedded Lights Out Manager Administration Guide for your server. Note The CLI commands, syntax, and namespaces in this section might be different from the commands, syntax, and namespaces used for your server see the Embedded Lights Out Manager Administration Guide for your server for the appropriate commands, syntax, and namespaces. Log in to the CLI, and navigate to the Tftp. Update directory. For example. cd SPTftp. Update5. Use the set command to set the IP address of the TFTP server. For example. set Server. IPxxx. xxx. xxx. IP address of the TFTP server. Use the set command to set the file name of the ELOM remote flash file. For example, for the Sun Fire X4. FilenameX4. 45. 0 4. B1. 77. Use the set command to start the TFTP download. Updateaction8. Select Yes to continue. SPTftp. Update set Server. IP1. 23. 4. 56. 7. File. NameX4. 45. B1. 7 set Updateactiongetting image. Update successful. The ELOM restarts. The BIOS version information is updated once the server is powered on. When the process finishes, boot the server. Repeat the migration process. To Recover the ILOM BIOS Firmware Using the Web GUI.